Rapidox SF6 6100 Pump Back-2

Full SF6 Gas Analyser

The Rapidox SF6 6100 Pump Back Analyser is a zero-emission, battery-powered multi-gas analyser for SF6, capable of measuring multiple gases simultaneously and installed in a rugged, portable case.

COD. ALY101-02

Request info
Features and benefits

Features and benefits

  • 01

    Full gas return function

  • 02

    8 measurable parameters

  • 03

    Portable

  • 04

    DN8 and DN20 coupling tongue parts

Technical specifications

Measure up to eight parameters including:

  • Sulphur Hexafluoride (0-100% SF6)
  • Sulphur Dioxide (0-100ppm * SO2)
  • Dew point (-60/20° Cdp H2O)
  • Carbon Tetrafluomethane (20-80% CF4)
  • Hydrofluoric acid (0-10ppm # HF)
  • Air (0-100%)
  • Carbon Monoxide (0-100ppm CO)
  • Hydrogen Sulphide (0-100ppm H2S)

Full gas return function (pumpback).

  • Mains voltage for charging

    90-260Vac 50/60 Hz

  • Main operation with battery

    UP TO 8 HOURS ON A SINGLE CHARGE 5-7 HOURS FOR A FULL RECHARGE FROM A DISCHARGED BATTERY

  • Gas return operation with battery

    UP TO 20 GAS RETURN CYCLES ON A SINGLE CHARGE 5-7 HOURS FOR A FULL CHARGE FROM LOW BATTERY

  • Analyser Dimensions

    L 570 mm, W 470 mm, H 280 mm

  • Weight

    21 kg (without accesories)

  • Gas storage bag

    Capacity 5 Liters s.l.m

  • Test duration time

    2 TO 8 MINUTES SELECTABLE BY THE USER. A MINIMUM OF 6 MINUTES IS REQUIRED FOR HUMIDITY MEASUREMENT

  • Display

    7″ FULL COLOR PC TOUCH SCREEN

  • Heating time

    15 MINUTES AT 20°C

  • Normal operating temperature

    10°C TO 40°C AMBIENT TEMPERATURE

  • Normal operating humidity

    AMBIENT HUMIDITY FROM 10 TO 90% RH

  • Normal operating pressure

    AMBIENT PRESSURE FROM 800 TO 1100 MBAR ABS

  • Minimum gas inlet pressure

    0.3 bar

  • Maximum gas inlet pressure

    10 bar

  • Maximum gas return compressor pressure

    10.5 bar

  • Sampling frequency

    IN TIMED OR CONTINUOUS MODE

  • SF6 sensor

    SCALE 0-100%, FULL SCALE ACCURACY +/- 0.5%

  • SO2 Sensor

    SCALE 0-100PPM (OR 0-500PPM), FULL SCALE ACCURACY +/- 2%.

  • H2O sensor

    FROM -60 TO +20°CDP, FULL SCALE ACCURACY +/- 2°CDP (OPTIONAL DISPLAY CORRECTED TO 20°C AVAILABLE)

  • CF4 Sensor

    SCALE>20 <80%, CALCULATED AS PROPORTIONATE GAS

  • HF sensor

    0-10PPM SCALE (0-20 AND 0-30PPM RANGES AVAILABLE ON REQUEST), +/-2% FULL SCALE ACCURACY

  • Air or N2

    SCALE 0-100%, +/-2% FULL SCALE ACCURACY

  • CO and H2S sensor

    SCALE 0-1000PPM, FULL SCALE ACCURACY +/- 2%

Other products

They might interest you

strumenti di misura sf6

Products SF6

Easy

Details

Products SF6

Active

Details
filtraggio-sf6

Products SF6

Pure

Details

Products SF6

Flow V0

Details

Accessories

Scales

Details

Adapters, Tubes, Valves

DN8 Adapter Set

Details

Adapters, Tubes, Valves

Manifold
4xDN20 + 1xDN8

Details

Products SF6

Flow V1

Details

Products SF6

VacuumFlow

Details

Products SF6

Sniffer SF6

Details

Products SF6

ESAVan

Details
strumenti di misura sf6

Products SF6

Easy Dry

Details

Adapters, Tubes, Valves

4-Way Distributor

Details

Adapters, Tubes, Valves

Safety Valves

Details

Adapters, Tubes, Valves

4m Long Hose for Analysis

Details

Adapters, Tubes, Valves

Storage hose connection DN8

Details

Adapters, Tubes, Valves

Cylinder connections

Details

Adapters, Tubes, Valves

DN20 Adapter Set

Details

Adapters, Tubes, Valves

Adapters and Valves
DN8/DN20

Details

Adapters, Tubes, Valves

DN8 rubber hoses

Details

Adapters, Tubes, Valves

DN20 rubber hoses

Details

Adapters, Tubes, Valves

Wire braided hoses

Details
+39 035 4376691