SF6 Gas Analyser

Available in two different versions to meet all SF6 analysis’ need:

COD. ALY101-03 3 cells Analysers
COD. ALY101-04 8 cells Analysers

Request info
Features and benefits

Features and benefits

  • 01

    Full gas return function (Pumpback) and special flexible bag for storage

  • 02

    COD. ALY101-03: 3 different measurable parameters to verify the purity of the gas according to the CEI EN 60480

  • 03

    COD. ALY101-03: 8 different measurable parameters to verify the purity of the gas according to the CEI EN 60480

  • 04

    Portable

  • 05

    DN8 and DN20 coupling tongue parts

Technical specifications

• The absence of SF6 gas leaks is guaranteed by a closed-loop system
• Special flexible bag for storage
Maximum safety for the equipment: the sample hose and storage bag can be vacuum purged before testing to ensure no mixing of contaminated gas occurs

COD. ALY101-03 3 parameters: SF6 SO2 e H2O
COD. ALY101-04 8 parameters: SF6 SO2 H2O CF4 HF aria CO H2S

  • Mains voltage for charging

    90-260Vac 50/60 Hz

  • Main operation with battery

    Up to 8 hours with a single charge 5-7 hours for a full charge from low battery

  • Gas return operation with battery

    Up to 12 gas return cycles with a single 5-7 hours charge for a full charge from low battery

  • Analyser Dimensions

    L 570 mm, W 470 mm, H 280 mm

  • Weight

    21 kg without accessories

  • Gas storage bag

    Capacity 5 Liters s.l.m.

  • Test duration time

    2 to 8 minutes selectable by the user a minimum of 6 minutes is required for moisture measurement

  • Display

    7″ full colour PC touch screen

  • Heating time

    15 minutes at 20°C

  • Normal operating temperature

    Ambient temperature -10 C to 40°C

  • Normal operating humidity

    Ambient humidity 10 to 90% RH

  • Normal operating pressure

    Ambient pressure 800 to 1100 mbar abs.

  • Minimum gas inlet pressure

    0.3 bar

  • Maximum gas inlet pressure

    35 bar

  • Maximum gas return compressor pressure

    10.5 bar

  • Sampling frequency

    in time-based or continuous mode

  • SF6 sensor

    Scale 0-100%
    Full scale accuracy +/- 0.5%

  • SO2 Sensor

    0-100ppm or 0-150ppm or 0-500ppm scale
    Full scale accuracy +/- 2%

  • H2O sensor

    -60 to +20° Cdp
    Full scale accuracy +/- 2,0 Cdp Optional display corrected to 20°C

  • CF4 sensor

    Scale>20 <80%
    Calculated as gas in proportion

  • HF sensor

    Scale 0-10ppm (flow rates 0-20ppm and 0-30 available on request.
    Full scale accuracy +/- 2%

  • Air or N2 sensor

    Scale 0-100%
    Full scale accuracy +/- 2%

  • CO and H2S sensor

    Scale 0-1000ppm.
    Full scale accuracy +/- 2%

Other products

They might interest you

Products SF6

Easy

Details

Products SF6

Synergic

Details

Products SF6

Basic

Details

Products SF6

Active

Details

Air Evacuation

Vacuum Pump

Details

Accessories

Scales

Details

Products SF6

Flow V0

Details

Products SF6

Flow V1

Details

Products SF6

Sniffer SF6

Details

Products SF6

ESAVan

Details

Adapters, Tubes, Valves

4m Long Hose for Analysis

Details

Adapters, Tubes, Valves

Storage hose connection DN8

Details

Adapters, Tubes, Valves

Cylinder connections

Details

Adapters, Tubes, Valves

DN20 Adapter Set

Details

Adapters, Tubes, Valves

Adapters and Valves
DN8/DN20

Details

Adapters, Tubes, Valves

DN8 Adapter Set

Details

Adapters, Tubes, Valves

DN8 rubber hoses

Details

Adapters, Tubes, Valves

DN20 rubber hoses

Details

Adapters, Tubes, Valves

Stainless steel pipes

Details

Adapters, Tubes, Valves

Wire braided hoses

Details

Adapters, Tubes, Valves

Manifold
4xDN20 + 1xDN8

Details

Products SF6

VacuumFlow

Details

Adapters, Tubes, Valves

4-Way Distributor

Details

Adapters, Tubes, Valves

Safety Valves

Details
+39 035 4376691