{"id":5757,"date":"2026-07-06T10:34:29","date_gmt":"2026-07-06T08:34:29","guid":{"rendered":"https:\/\/www.synecom.it\/patented-solutions\/riciclo\/"},"modified":"2026-07-27T10:15:50","modified_gmt":"2026-07-27T08:15:50","slug":"sf-6-gas-recycling","status":"publish","type":"page","link":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/","title":{"rendered":"SF\u2086 GAS RECYCLING"},"content":{"rendered":"\n<section class=\"has-white-light-background-color container-fluid py-4 py-md-5 block-text-image\" id=\"block-text-image-block_932b35f9328068d5c4839dfa32e3bd19\">\n\t\n\t<div class=\"row align-items-center\">\n\t\t<div class=\"col-lg-4 offset-lg-1 col-md-6 order-md-2 order-1\">\n\t\t\t\t\t\t<figure class=\"full-img-container full-img-block-text-image rounded-5 overflow-hidden\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/resize-active-3.webp\" alt=\"\" class=\"img-fluid full-img\" \/>\n\t\t\t<\/figure>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-5 offset-lg-1 col-md-6 d-flex flex-column justify-content-between py-md-5 order-md-1 order-2\">\n\n\t\t\t\t\t\t<div class=\"h2 mb-5 c-primary\"><p>The Strategic Necessity of SF\u2086 Gas Recycling<\/p>\n<\/div>\n\t\t\t\n\t\t\t<div class=\"pt-md-5\">\n\t\t\t\t\t\t\t\t<div class=\"block-text-image-descr mb-4\"><p>Continuous network performance cannot rely on reactive solutions. Waiting for gas to become contaminated represents a huge operational risk: accumulated <b>moisture<\/b> compromises the insulating capacity of SF\u2086 and conducts electricity, favoring the formation of dangerous <b>electrical<\/b> <b>arcs<\/b>, while <b>acidic<\/b> <b>substances<\/b> corrode and damage the plant from within.<\/p>\n<p>Intervening promptly and directly on-site eliminates these threats before they turn into structural failure. On-site dialysis addresses this problem at the source: by continuously filtering and purifying corrosive impurities while the plant remains completely online, it protects your equipment, guarantees network stability, and extends the <b>operational<\/b><b> life<\/b> of existing assets.<\/p>\n<p><b>The 2035 <\/b><b>Maintenance<\/b><b> Standard<\/b> Under the strict <b>EU <\/b><b>Regulation<\/b><b> 2024\/573<\/b>, the countdown has already begun. By January 1st, 2035, the use of virgin SF\u2086 for maintenance will be completely prohibited. From that date, recycled or regenerated gas will be the only compliant standard allowed to keep your network alive.<\/p>\n<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-1 order-3\"><\/div>\n\t<\/div>\n\n<\/section>\n\n\n<section class=\"has-white-light-background-color container-fluid py-4 py-md-5 block-text-image\" id=\"block-text-image-block_acff3908ced325c239b778a01858b91b\">\n\t\n\t<div class=\"row align-items-center\">\n\t\t<div class=\"col-lg-4 offset-lg-1 col-md-6\">\n\t\t\t\t\t\t<figure class=\"full-img-container full-img-block-text-image rounded-5 overflow-hidden\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_hyperrealistic-photo-ultra-detailed-portrait-8k-resolution-crisp-facial-features-533011-2.png\" alt=\"\" class=\"img-fluid full-img\" \/>\n\t\t\t<\/figure>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-5 offset-lg-1 col-md-6 d-flex flex-column justify-content-between py-md-5\">\n\n\t\t\t\t\t\t<div class=\"h2 mb-5 c-primary\"><p>Why Choose Active: The Triple Benefit of Our Patented System<\/p>\n<\/div>\n\t\t\t\n\t\t\t<div class=\"pt-md-5\">\n\t\t\t\t\t\t\t\t<div class=\"block-text-image-descr mb-4\"><p>While traditional methods treat SF\u2086 gas contamination reactively, Synecom&#8217;s patented <b>ACTIVE system<\/b> introduces on-line dialysis, intervening before plant efficiency is compromised:<\/p>\n<p>1.<b>Environment: Resource <\/b><b>Conservation<\/b><b> and <\/b><b>Circular<\/b><b> Economy<\/b><\/p>\n<p>The environmental impact of untreated gas is not limited to waste management but directly affects the lifecycle of components:<\/p>\n<ul>\n<li><b>Reduction<\/b><b> of <\/b><b>indirect<\/b><b> carbon footprint:<\/b> If moisture and acid substances reduce the useful life of SF\u2086-insulated compartments, early asset replacement becomes necessary. Producing, transporting, and installing new primary equipment (steel, copper, heavy carpentry) requires enormous energy and resource consumption. <b>ACTIVE<\/b> extends the useful life of the existing plant, guaranteeing true sustainability.<\/li>\n<li><b>Zero-<\/b><b>mile<\/b> <b>circularity<\/b><b>:<\/b> Regenerates SF\u2086 directly within the same compartment, zeroing out emissions linked to the logistical transport of cylinders by road and thermal destruction processes.<\/li>\n<\/ul>\n<p>1.<b>Laws: Early Compliance and Strategic <\/b><b>Safety<\/b><\/p>\n<p>The <b>ACTIVE system<\/b> simplifies the transition toward new European industrial standards:<\/p>\n<ul>\n<li>Guarantees full regulatory compliance with <b>EU <\/b><b>Regulation<\/b><b> 2024\/573<\/b> years ahead of the 2035 deadline, which requires the use of recycled gas for top-ups, service, or maintenance.<\/li>\n<li>Makes your company autonomous in gas recycling at technical grade, eliminating dependence on a market for virgin SF\u2086 destined to disappear.<\/li>\n<\/ul>\n<p>1.<b>Extending<\/b> <b>Useful<\/b><b> Life: <\/b><b>Preventing<\/b> <b>Downtime<\/b><b> and <\/b><b>Internal<\/b> <b>Protection<\/b><\/p>\n<p>The system acts preventively while the plant is at full load and energized, without altering normal network operations:<\/p>\n<ul>\n<li><b>Zero service <\/b><b>interruptions<\/b><b>:<\/b> Filtration happens continuously and in total safety, eliminating the need to plan costly downtime or compartment emptying.<\/li>\n<li><b>Component <\/b><b>integrity<\/b><b>:<\/b> By constantly removing moisture (avoiding electricity conduction and electrical arcs) and neutralizing acidity, internal materials are protected from premature aging, adding decades of safe operation to your assets.<\/li>\n<\/ul>\n<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-1 order-3\"><\/div>\n\t<\/div>\n\n<\/section>\n\n\n<section class=\"has-white-light-background-color container-fluid py-4 py-md-5 block-text-image\" id=\"block-text-image-block_7aadefab44ad494cc637b1d097710bef\">\n\t\n\t<div class=\"row align-items-center\">\n\t\t<div class=\"col-lg-4 offset-lg-1 col-md-6 order-md-2 order-1\">\n\t\t\t\t\t\t<figure class=\"full-img-container full-img-block-text-image rounded-5 overflow-hidden\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_hyperrealistic-photo-ultra-detailed-portrait-8k-resolution-crisp-facial-features-533011-1-1.png\" alt=\"\" class=\"img-fluid full-img\" \/>\n\t\t\t<\/figure>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-5 offset-lg-1 col-md-6 d-flex flex-column justify-content-between py-md-5 order-md-1 order-2\">\n\n\t\t\t\t\t\t<div class=\"h2 mb-5 c-primary\"><p>The Result: Certified Technical Grade Quality<\/p>\n<\/div>\n\t\t\t\n\t\t\t<div class=\"pt-md-5\">\n\t\t\t\t\t\t\t\t<div class=\"block-text-image-descr mb-4\"><p>Recycling does not consist of altering the gas mixture or increasing the percentage of SF\u2086 present; for total molecular separation and gas concentration, a <b>cryogenic<\/b> <b>regeneration<\/b> process would be required. Recycling focuses on ensuring the existing volume of gas is completely clean and safe to use. Thanks to our patented variable-capacity filtration system, the <b>Active<\/b> system identifies and eliminates the true &#8220;killers&#8221; of your compartments: <b>moisture<\/b><b>, <\/b><b>dust<\/b><b>, and corrosive <\/b><b>acidic<\/b><b> by-products<\/b>.<\/p>\n<p>The result is a volume of gas restored perfectly according to <b>IEC 60480<\/b> technical grade standards for reused SF\u2086. Even if your gas contains small fractions of other non-reactive gases, <b>Active<\/b> ensures the SF\u2086 itself is completely dry, neutralized, and harmless to equipment. You thus obtain a safe and clean operating environment entirely on-site and with infrastructure fully energized, all supported by integrated multi-parameter transmitters that monitor <b>dew<\/b><b> point, pressure, and <\/b><b>density<\/b> in real-time.<\/p>\n<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-1 order-3\"><\/div>\n\t<\/div>\n\n<\/section>\n\n\n<section class=\"has-white-light-background-color container-fluid py-4 py-md-5 block-text-image\" id=\"block-text-image-block_4fa5d4581368d4465f2fd0f3d2efc9b6\">\n\t\n\t<div class=\"row align-items-center\">\n\t\t<div class=\"col-lg-4 offset-lg-1 col-md-6\">\n\t\t\t\t\t\t<figure class=\"full-img-container full-img-block-text-image rounded-5 overflow-hidden\">\n\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/resize-active-4-1.jpg\" alt=\"\" class=\"img-fluid full-img\" \/>\n\t\t\t<\/figure>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-5 offset-lg-1 col-md-6 d-flex flex-column justify-content-between py-md-5\">\n\n\t\t\t\t\t\t<div class=\"h2 mb-5 c-primary\"><p>Two solutions to optimize on-site recycling<\/p>\n<\/div>\n\t\t\t\n\t\t\t<div class=\"pt-md-5\">\n\t\t\t\t\t\t\t\t<div class=\"block-text-image-descr mb-4\"><p>Whether you prefer to entrust the process to a team of specialists or equip your operators with our technology, we offer the perfect model for your operational scale:<\/p>\n<p>1.<b>The Synecom on-site <\/b><b>dialysis<\/b><b> service<\/b> <b>Zero <\/b><b>logistical<\/b> <b>complications<\/b>, no gas transport, and <b>no <\/b><b>operational<\/b> <b>interruption<\/b>. Our highly qualified and certified technicians intervene directly at your facility with the <b>patented<\/b><b> Active mobile <\/b><b>unit<\/b>. We manage the entire <b>end-to-end <\/b><b>recycling<\/b> <b>process<\/b> directly on your <b>energized<\/b> <b>switchgear<\/b>, guaranteeing full compliance and maximum safety, while your team can continue to focus on core activities.<\/p>\n<p>2.<b>ACTIVE: Complete <\/b><b>operational<\/b> <b>autonomy<\/b> Ready to take <b>full control of <\/b><b>your<\/b> <b>network&#8217;s<\/b><b> preventive <\/b><b>maintenance<\/b>? You can integrate the <b>patented<\/b><b> Active mobile <\/b><b>unit<\/b> directly into your facility or service fleet. Thanks to the <b>intelligent<\/b><b> and <\/b><b>automated<\/b> <b>interface<\/b>, <b>Plug-and-Play filters<\/b>, and the highly mobile design, your technicians will be able to perform <b>in-line gas <\/b><b>recycling<\/b> and work on <b>energized<\/b> <b>equipment<\/b> in total autonomy, on assets of any size and at any time.<\/p>\n<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\n\t\t<div class=\"col-lg-1 order-3\"><\/div>\n\t<\/div>\n\n<\/section>\n\n\n<section class=\"container-fluid pt-5\" id=\"title-descr-block_d295a1d1622c193195bfbdf7596cd6be\">\n\t<div class=\"row justify-content-center\">\n\n\t\t<div class=\"col-md-10\">\n\n\t\t\t<div class=\"row align-items-end border-bottom g-0 pb-md-5 pb-4 mb-4\">\n\t\t\t\t<div class=\"col-md-8\">\n\t\t\t\t\t<div class=\"h2 c-primary\"><p>Recycling vs. SF\u2086 Regeneration: A direct comparison<\/p>\n<\/div>\n\t\t\t\t\t<div><p>The choice between recycling and regeneration depends strictly on your operational needs and the specific state of the gas. Today, <b>Synecom<\/b> guarantees you maximum flexibility on both paths, offering each technology both as a service and as a product.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/div>\n\n\t\t<\/div>\n\t\t\n\t<\/div>\n<\/section>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<section class=\"container-fluid pt-5\">\n\t<div class=\"row justify-content-center\">\n\n\t\t<div class=\"col-md-10\">\n\t\t\t\n\t\t\t<table class=\"rwd-table\">\n\n\t\t\t\t\n\t\t\t\t\t\t\t\t<thead>\n\t\t\t\t\t<tr>\n\n\t\t\t\t\t\t\t\t\t\t\t<th>\n\t\t\t\t\t\t\tFeature\n\t\t\t\t\t\t<\/th>\n\t\t\t\t\t\t\t\t\t\t\t<th>\n\t\t\t\t\t\t\tSF\u2086 Recycling (Frontline Maintenance)\n\t\t\t\t\t\t<\/th>\n\t\t\t\t\t\t\t\t\t\t\t<th>\n\t\t\t\t\t\t\tSF\u2086 Regeneration (Molecular Rebirth)\n\t\t\t\t\t\t<\/th>\n\t\t\t\t\t\n\t\t\t\t\t<\/tr>\n\t\t\t\t<\/thead>\n\t\t\t\t\n\t\t\t\t<tbody>\n\n\t\t\t\t\n\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"Feature\n\">\n\t\t\t\t\t\t\t\tConfiguration\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Recycling (Frontline Maintenance)\n\">\n\t\t\t\t\t\t\t\t100% Mobile and On-site\nPerformed directly at your facility.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Regeneration (Molecular Rebirth)\n\">\n\t\t\t\t\t\t\t\tFixed Industrial Infrastructure\n\nRequires a dedicated, permanent factory or station area.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\n\t\t\t\t\n\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"Feature\n\">\n\t\t\t\t\t\t\t\tPlant Operating Condition\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Recycling (Frontline Maintenance)\n\">\n\t\t\t\t\t\t\t\tZero downtime.\n\nThe process is performed online while equipment is fully energized.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Regeneration (Molecular Rebirth)\n\">\n\t\t\t\t\t\t\t\tShutdown required.\n\nGas must be evacuated into cylinders, requiring a temporary planned shutdown\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\n\t\t\t\t\n\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"Feature\n\">\n\t\t\t\t\t\t\t\tTarget Contaminants\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Recycling (Frontline Maintenance)\n\">\n\t\t\t\t\t\t\t\tMoisture, dust, and acidic byproducts.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Regeneration (Molecular Rebirth)\n\">\n\t\t\t\t\t\t\t\tMoisture, dust, acidic byproducts, and air.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\n\t\t\t\t\n\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"Feature\n\">\n\t\t\t\t\t\t\t\tImpact on Gas Ratio\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Recycling (Frontline Maintenance)\n\">\n\t\t\t\t\t\t\t\tDehumidifies and removes acidic substances from the existing mixture.\nDoes not alter gas concentration; it removes harmful impurities from the SF\u2086 volume.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Regeneration (Molecular Rebirth)\n\">\n\t\t\t\t\t\t\t\tCryogenically separates the pure SF\u2086 molecule from all other gaseous compounds, including air.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\n\t\t\t\t\n\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"Feature\n\">\n\t\t\t\t\t\t\t\tFinal Quality Standard\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Recycling (Frontline Maintenance)\n\">\n\t\t\t\t\t\t\t\tTechnical Grade (IEC 60480)\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Regeneration (Molecular Rebirth)\n\">\n\t\t\t\t\t\t\t\tUltra-Pure &gt;99.9992% (IEC 60376)\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\n\t\t\t\t\n\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"Feature\n\">\n\t\t\t\t\t\t\t\tAccess Mode\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Recycling (Frontline Maintenance)\n\">\n\t\t\t\t\t\t\t\t\u2022 Service: We come to you with the Active unit.\n\u2022 Product: You purchase the mobile Active unit.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<td data-th=\"SF\u2086 Regeneration (Molecular Rebirth)\n\">\n\t\t\t\t\t\t\t\t\u2022 Service: You ship cylinders to our nearest center.\n\u2022 Product: You purchase the turnkey REGEN2 plant.\n\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\n\t\t\t\t\n\t\t\t\t<\/tbody>\n\n\t\t\t<\/table>\n\n\t\t\t\t\t<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<section class=\"container-fluid pt-5\" id=\"title-descr-block_2cd623cfcfe7665ad3d920321c64fa75\">\n\t<div class=\"row justify-content-center\">\n\n\t\t<div class=\"col-md-10\">\n\n\t\t\t<div class=\"row align-items-end border-bottom g-0 pb-md-5 pb-4 mb-4\">\n\t\t\t\t<div class=\"col-md-8\">\n\t\t\t\t\t<div class=\"h2 c-primary\"><p>The strategic conclusion for your network<\/p>\n<\/div>\n\t\t\t\t\t<div><\/div>\n\t\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<\/div>\n\n\t\t<\/div>\n\t\t\n\t<\/div>\n<\/section>\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex row px-0\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow col\" style=\"flex-basis:8.3%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow col\" style=\"flex-basis:41.66%\">\n<h6 class=\"wp-block-heading has-primary-color has-text-color has-link-color wp-elements-1\"><strong><strong>When to choose Recycling<\/strong><\/strong><\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">As a routine preventive mechanism with zero downtime. It is the most convenient and rapid solution to keep your energized assets dry, free of acidic compounds, and fully operational all year round, without any interruption of the electrical grid.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow col\" style=\"flex-basis:41.66%\">\n<h6 class=\"wp-block-heading has-primary-color has-text-color has-link-color wp-elements-2\"><strong><strong>When to choose Regeneration<\/strong><\/strong><\/h6>\n\n\n\n<p class=\"wp-block-paragraph\">When gas is heavily contaminated or mixed with air\/nitrogen, or during major decommissioning projects. This process prevents gas from being wasted and disposed of as expensive non-compliant special waste.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow col\" style=\"flex-basis:8.33%\"><\/div>\n<\/div>\n<\/div><\/div>\n\n\n<section class=\"container pt-5\">\n\t<div class=\"row mt-md-5\">\n\t\t<div class=\"col-lg-4 col-md-5 mt-md-5 pt-md-5 mt-4\">\n\t\t\t<div class=\"h6 c-secondary mb-1\"><p>Frequently Asked Question<\/p>\n<\/div>\n\t\t\t\n\t\t\t<div class=\"h2 c-primary mb-2\"><p>What you need to know<\/p>\n<\/div>\n\n\t\t\t<div class=\"mb-2\"><p>For specific requirements, contact our engineering team<\/p>\n<\/div>\n\t\t<\/div>\n\n\t\t<div class=\"col-md-7 offset-lg-1 mt-md-5 pt-md-5 mt-4\">\n\t\t\t\t\t\t\t\t\t<div id=\"accordion-block_c14407e6d0861a9b79f25211b74bf29c\" class=\"accordion-faq accordion\">\n\t\t\t\t\t\t\t\t<div class=\"accordion-item\">\n\t\t\t\t\t<a class=\"accordion-header\" id=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-1\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-1\" aria-expanded=\"false\" aria-controls=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-1\">\n\t\t\t\t\t\t<div class=\"row align-items-center\">\n\t\t\t\t\t\t\t<div class=\"col-10\">\n\t\t\t\t\t\t\t\t<div class=\"h6 c-primary mb-0\"><p>How does the &#8220;online&#8221; dialysis process work safely without triggering network low-pressure alarms?<\/p>\n<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"col-2 d-flex flex-row justify-content-end\">\n\t\t\t\t\t\t\t\t<div class=\"accordion-arrow\">\n\t\t\t\t\t\t\t\t\t<div class=\"plus-minus-toggle\"><\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/a>\n\n\t\t\t\t\t<div id=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-1\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-1\" data-bs-parent=\"#accordion-block_c14407e6d0861a9b79f25211b74bf29c\">\n\t\t\t\t\t\t<div class=\"accordion-body\">\n\t\t\t\t\t\t\t<p>This is the technological heart of our patent. The <b>Active <\/b><b>unit<\/b> is specifically designed to connect in total safety to energized and fully operational switchgear. The system draws only a small, precisely calculated volume of gas, filters it, and reintroduces it into the circuit through a continuous, automated cycle. This advanced pressure balancing system ensures that the internal density of the compartment remains constant, eliminating the risk of triggering low-pressure alarms or causing network interruptions at the root.<\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"accordion-item\">\n\t\t\t\t\t<a class=\"accordion-header\" id=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-2\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-2\" aria-expanded=\"false\" aria-controls=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-2\">\n\t\t\t\t\t\t<div class=\"row align-items-center\">\n\t\t\t\t\t\t\t<div class=\"col-10\">\n\t\t\t\t\t\t\t\t<div class=\"h6 c-primary mb-0\"><p>Does recycling increase the percentage or effective concentration of SF\u2086 in the gas mixture?<\/p>\n<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"col-2 d-flex flex-row justify-content-end\">\n\t\t\t\t\t\t\t\t<div class=\"accordion-arrow\">\n\t\t\t\t\t\t\t\t\t<div class=\"plus-minus-toggle\"><\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/a>\n\n\t\t\t\t\t<div id=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-2\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-2\" data-bs-parent=\"#accordion-block_c14407e6d0861a9b79f25211b74bf29c\">\n\t\t\t\t\t\t<div class=\"accordion-body\">\n\t\t\t\t\t\t\t<p>No. Recycling is a purification process, not one of molecular concentration; consequently, it does not separate or remove foreign gases (such as air or nitrogen) already mixed in. Its goal is the deep purification of the existing gas volume. <b>Active<\/b> intervenes in a targeted manner on the true operational threats (<b>moisture<\/b><b>, <\/b><b>dust<\/b><b>, and corrosive <\/b><b>acidic<\/b><b> by-products<\/b>) ensuring the SF\u2086 present remains perfectly clean, dry, and fully compliant with the <b>IEC 60480 standard<\/b>, thus blocking internal degradation.<\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"accordion-item\">\n\t\t\t\t\t<a class=\"accordion-header\" id=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-3\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-3\" aria-expanded=\"false\" aria-controls=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-3\">\n\t\t\t\t\t\t<div class=\"row align-items-center\">\n\t\t\t\t\t\t\t<div class=\"col-10\">\n\t\t\t\t\t\t\t\t<div class=\"h6 c-primary mb-0\"><p>Can our operators use the Active unit autonomously? How complex is maintenance?<\/p>\n<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"col-2 d-flex flex-row justify-content-end\">\n\t\t\t\t\t\t\t\t<div class=\"accordion-arrow\">\n\t\t\t\t\t\t\t\t\t<div class=\"plus-minus-toggle\"><\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/a>\n\n\t\t\t\t\t<div id=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-3\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-3\" data-bs-parent=\"#accordion-block_c14407e6d0861a9b79f25211b74bf29c\">\n\t\t\t\t\t\t<div class=\"accordion-body\">\n\t\t\t\t\t\t\t<p>Absolutely yes. By choosing to purchase the <b>Active <\/b><b>unit<\/b>, your team will gain total operational autonomy in managing preventive maintenance cycles. The machine is equipped with an intuitive and highly automated interface that monitors parameters in real-time. Furthermore, the patented integrated filters leverage a <b>&#8220;Plug &amp; Play&#8221; design<\/b> with molecular sealing valves: this allows technicians to replace filters in total safety while the equipment is running, guaranteeing zero gas leakage and zero system downtime.<\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<div class=\"accordion-item\">\n\t\t\t\t\t<a class=\"accordion-header\" id=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-4\" data-bs-toggle=\"collapse\" data-bs-target=\"#collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-4\" aria-expanded=\"false\" aria-controls=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-4\">\n\t\t\t\t\t\t<div class=\"row align-items-center\">\n\t\t\t\t\t\t\t<div class=\"col-10\">\n\t\t\t\t\t\t\t\t<div class=\"h6 c-primary mb-0\"><p>What is the main difference between SF\u2086 recycling and regeneration?<\/p>\n<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"col-2 d-flex flex-row justify-content-end\">\n\t\t\t\t\t\t\t\t<div class=\"accordion-arrow\">\n\t\t\t\t\t\t\t\t\t<div class=\"plus-minus-toggle\"><\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/a>\n\n\t\t\t\t\t<div id=\"collapse-accordion-block_c14407e6d0861a9b79f25211b74bf29c-4\" class=\"accordion-collapse collapse\" aria-labelledby=\"heading-accordion-block_c14407e6d0861a9b79f25211b74bf29c-4\" data-bs-parent=\"#accordion-block_c14407e6d0861a9b79f25211b74bf29c\">\n\t\t\t\t\t\t<div class=\"accordion-body\">\n\t\t\t\t\t\t\t<p>The fundamental difference lies in the contamination state of the gas and the logistical method of treatment:<\/p>\n<p><b>Recycling<\/b> (via the Active unit) is a 100% mobile and on-site solution (available both as a service and as a product purchase), designed to remove moisture and acids directly from energized equipment, without any plant downtime.<\/p>\n<p><b>Regeneration<\/b> is an industrial process (performed at our specialized center or via the <b>REGEN2<\/b> turnkey plant) that uses a proprietary cryogenic technology to physically separate the SF\u2086 molecule from non-condensable contaminants such as air, nitrogen, or CF\u2084, restoring gas purity to an ultra-pure standard (&gt;99.9992%) superior to new.<\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>When to choose Recycling As a routine preventive mechanism with zero downtime. It is the most convenient and rapid solution to keep your energized assets dry, free of acidic compounds, and fully operational all year round, without any interruption of the electrical grid. When to choose Regeneration When gas is heavily contaminated or mixed with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8844,"parent":5706,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-5757","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SF\u2086 GAS RECYCLING - Synecom SF6<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SF\u2086 GAS RECYCLING - Synecom SF6\" \/>\n<meta property=\"og:description\" content=\"When to choose Recycling As a routine preventive mechanism with zero downtime. It is the most convenient and rapid solution to keep your energized assets dry, free of acidic compounds, and fully operational all year round, without any interruption of the electrical grid. When to choose Regeneration When gas is heavily contaminated or mixed with [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/\" \/>\n<meta property=\"og:site_name\" content=\"Synecom SF6\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-27T08:15:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753-972x1024.png\" \/>\n\t<meta property=\"og:image:width\" content=\"972\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/\",\"url\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/\",\"name\":\"SF\u2086 GAS RECYCLING - Synecom SF6\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.synecom.it\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.synecom.it\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753.png\",\"datePublished\":\"2026-07-06T08:34:29+00:00\",\"dateModified\":\"2026-07-27T08:15:50+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.synecom.it\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753.png\",\"contentUrl\":\"https:\\\/\\\/www.synecom.it\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753.png\",\"width\":1785,\"height\":1880},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/sf-6-gas-recycling\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Patented solutions\",\"item\":\"https:\\\/\\\/www.synecom.it\\\/en\\\/patented-solutions\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SF\u2086 GAS RECYCLING\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.synecom.it\\\/#website\",\"url\":\"https:\\\/\\\/www.synecom.it\\\/\",\"name\":\"Synecom SF6\",\"description\":\"A new age of SF&lt;sub&gt;6&lt;\\\/sub&gt; sustainability\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.synecom.it\\\/#organization\"},\"alternateName\":\"Synecom SF6\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.synecom.it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.synecom.it\\\/#organization\",\"name\":\"Synecom SF6\",\"alternateName\":\"Synecom SF6\",\"url\":\"https:\\\/\\\/www.synecom.it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.synecom.it\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.synecom.it\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/logo-synecom-sf6.svg\",\"contentUrl\":\"https:\\\/\\\/www.synecom.it\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/logo-synecom-sf6.svg\",\"width\":800,\"height\":220,\"caption\":\"Synecom SF6\"},\"image\":{\"@id\":\"https:\\\/\\\/www.synecom.it\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SF\u2086 GAS RECYCLING - Synecom SF6","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/","og_locale":"en_US","og_type":"article","og_title":"SF\u2086 GAS RECYCLING - Synecom SF6","og_description":"When to choose Recycling As a routine preventive mechanism with zero downtime. It is the most convenient and rapid solution to keep your energized assets dry, free of acidic compounds, and fully operational all year round, without any interruption of the electrical grid. When to choose Regeneration When gas is heavily contaminated or mixed with [&hellip;]","og_url":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/","og_site_name":"Synecom SF6","article_modified_time":"2026-07-27T08:15:50+00:00","og_image":[{"width":972,"height":1024,"url":"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753-972x1024.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/","url":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/","name":"SF\u2086 GAS RECYCLING - Synecom SF6","isPartOf":{"@id":"https:\/\/www.synecom.it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/#primaryimage"},"image":{"@id":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/#primaryimage"},"thumbnailUrl":"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753.png","datePublished":"2026-07-06T08:34:29+00:00","dateModified":"2026-07-27T08:15:50+00:00","breadcrumb":{"@id":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/#primaryimage","url":"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753.png","contentUrl":"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/Firefly_Enhance-image-quality-ultra-high-resolution-sharp-focus-crisp-details-crystal-cle-22882_12f43d66-1-e1784559677753.png","width":1785,"height":1880},{"@type":"BreadcrumbList","@id":"https:\/\/www.synecom.it\/en\/patented-solutions\/sf-6-gas-recycling\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.synecom.it\/en\/"},{"@type":"ListItem","position":2,"name":"Patented solutions","item":"https:\/\/www.synecom.it\/en\/patented-solutions\/"},{"@type":"ListItem","position":3,"name":"SF\u2086 GAS RECYCLING"}]},{"@type":"WebSite","@id":"https:\/\/www.synecom.it\/#website","url":"https:\/\/www.synecom.it\/","name":"Synecom SF6","description":"A new age of SF&lt;sub&gt;6&lt;\/sub&gt; sustainability","publisher":{"@id":"https:\/\/www.synecom.it\/#organization"},"alternateName":"Synecom SF6","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.synecom.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.synecom.it\/#organization","name":"Synecom SF6","alternateName":"Synecom SF6","url":"https:\/\/www.synecom.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.synecom.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/logo-synecom-sf6.svg","contentUrl":"https:\/\/www.synecom.it\/wp-content\/uploads\/2026\/07\/logo-synecom-sf6.svg","width":800,"height":220,"caption":"Synecom SF6"},"image":{"@id":"https:\/\/www.synecom.it\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/pages\/5757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/comments?post=5757"}],"version-history":[{"count":5,"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/pages\/5757\/revisions"}],"predecessor-version":[{"id":10635,"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/pages\/5757\/revisions\/10635"}],"up":[{"embeddable":true,"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/pages\/5706"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/media\/8844"}],"wp:attachment":[{"href":"https:\/\/www.synecom.it\/en\/wp-json\/wp\/v2\/media?parent=5757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}