The 600L Cylinder Scale allows you to determine the amount of gas introduced into a compartment during the filling process by weighing the cylinder.
COD. SCA102-01
Maximum reliability
Weighing accuracy over time
Equalized cells
Large safety margin even in adverse environmental conditions
Static overload protection at over 200% of nominal capacity
Load Cells
Shear Beam
Supply voltage
Max 15 VDC
Nominal Output
2 or 3 mV/V +/- 0,25 %
Combined Error
< 0,03 % FSO
Temperature compensation
– 10 °C / + 40 °C
Working temperature range
– 18 °C / + 65 °C
Cell resistance – Input
350 Ohm
Cell Resistance – Output
350 Ohm
Dimensions
DEPENDING ON MODEL
Maximum Load
DEPENDING ON MODEL